This site uses cookies. For more information, please see our Privacy Policy
Contact Us
Lastronic Corporation
  • About Us
  • Agent Brand
    • CS instruments-Gas flow and quality measurment
    • Datapaq-Oven Temperature Profiling System
    • Lastronic-Own-brand
    • Air Monitor-Flow tube measurment
    • Testo-Flue gas analyzer and flow measurment
    • iButton-Button-type temperature recorder
    • ACR-compact data recorder
    • Trotec-Multi-parameter Environmental Sensor
    • QbyV-Can quality control machine
  • Product Categories
  • Calibration Services
  • Case Studies
  • Latest News
  • Contact Us
  • Monitoring sensors
    • Gas Flow Meter
    • Steam Vortex Flow Meter
    • HVAC Duct Airflow Meter
    • liquid flow meter
    • Dew point measurement
    • Liquid Level Measurement
    • Temperature and Humidity Measurement
    • Pressure gauge + differential pressure gauge
    • Digital Panel Meter
    • Measurement of residual oil particles in piping
    • flow switch
    • thickness gauge
    • Multi-channel data logger
    • Hot tapping on gas pipelines
  • QC and Portable equipment
    • Datapaq Thermal Profiling System
    • iButton Thermochron Data Logger
    • Boiler Combustion Efficiency Analyzer
    • Gas Leak Detector
    • Anemometer
    • Hygrometer
    • Thermometer
    • Noise meter
    • Particle Counter
    • Endoscope
  • Liquid quality monitoring sensors
    • pH meter
    • Oxidation-Reduction Potential meter
    • Conductivity Meter
    • Dissolved Oxygen Meter
    • Water Hardness Tester
    • Turbidimeter
  • LoRa Wireless monitoring system
    • LoRa Wireless Instrumentation and Telemetry Transmission System
  • Gas Flow Meter Case Studies
    • Application of VA500 Thermal Mass Flow Meter in Natural Gas Measurement
MENU
( )
  • 繁中
  • EN
CLOSE
繁中 EN
  • About Us
  • Agent Brand
    • CS instruments-Gas flow and quality measurment
    • Datapaq-Oven Temperature Profiling System
    • Lastronic-Own-brand
    • Air Monitor-Flow tube measurment
    • Testo-Flue gas analyzer and flow measurment
    • iButton-Button-type temperature recorder
    • ACR-compact data recorder
    • Trotec-Multi-parameter Environmental Sensor
    • QbyV-Can quality control machine
  • Product Categories
    • Monitoring sensors
      • Gas Flow Meter
      • Steam Vortex Flow Meter
      • HVAC Duct Airflow Meter
      • liquid flow meter
      • Dew point measurement
      • Liquid Level Measurement
      • Temperature and Humidity Measurement
      • Pressure gauge + differential pressure gauge
      • Digital Panel Meter
      • Measurement of residual oil particles in piping
      • flow switch
      • thickness gauge
      • Multi-channel data logger
      • Hot tapping on gas pipelines
    • QC and Portable equipment
      • Datapaq Thermal Profiling System
      • iButton Thermochron Data Logger
      • Boiler Combustion Efficiency Analyzer
      • Gas Leak Detector
      • Anemometer
      • Hygrometer
      • Thermometer
      • Noise meter
      • Particle Counter
      • Endoscope
    • Liquid quality monitoring sensors
      • pH meter
      • Oxidation-Reduction Potential meter
      • Conductivity Meter
      • Dissolved Oxygen Meter
      • Water Hardness Tester
      • Turbidimeter
    • LoRa Wireless monitoring system
      • LoRa Wireless Instrumentation and Telemetry Transmission System
  • Calibration Services
  • Case Studies
    • Gas Flow Meter Case Studies
      • Application of VA500 Thermal Mass Flow Meter in Natural Gas Measurement
  • Latest News
  • Contact Us
  • Home
  • Agent Brand
  • CS instruments-Gas flow and quality measurment
  • Flow sensors
VD500 Insertion differential pressure flow Meter
1 / 4
  • VD500 Insertion differential pressure flow Meter
  • VD500 Insertion differential pressure flow Meter
  • VD500 Insertion differential pressure flow Meter
  • VD500 Insertion differential pressure flow Meter

VD500 Insertion differential pressure flow Meter

Germany- CS instruments
Description:

The VD500 Differential Pressure Gas Flow Meter from CS Instruments calculates the volume flow of compressed air or gases based on the Pitot tube measurement principle, and is classified as a differential pressure flow meter.
 

The VD500 is equipped with built-in pressure and temperature sensors for compensation, allowing it to accurately calculate the true instantaneous volume flow.
 

Designed by CS Instruments Germany, the flow meter features a hot-swappable installation, enabling it to be inserted or removed at any time without system shutdown, while still providing precise measurement of all types of dry gases.
 

Typical applications include air compressor outlet flow (FAD), exhaust gas monitoring, and more.

Download file

 Application

 
  • Air compressor outlet / single machine efficiency flow measurement – undried (FAD)
  • Clean compressed air system – dried (CDA)
  • Exhaust gas and gases with larger particles

 Advantage

 
  • Insertion design: Allows quick on-site installation and removal for maintenance without interrupting the pipeline system.
  • Pressure and temperature compensation: Can display actual volume flow (m³/h).
  • Multi-parameter measurement: Measures flow, totalized flow, temperature, and pressure simultaneously.
  • No heating element: Resistant to contamination, high temperatures, and particulates, making it ideal for industrial environments.
  • Low installation cost: Insertion design requires no full pipe cutting, suitable for large pipelines DN50–DN300 and above.
  • Handles high flow rates and high-pressure gases: Measurement accuracy is not affected by changes in flow velocity.

  Technical data

 
  • Latest technology: Minimum detectable flow velocity of 2 m/s, covering all flow ranges of variable-speed air compressors
  • Accuracy: ±1.5% of measured value (m.v.)
  • Power supply: 18…36 VDC, 5 W
  • Communication interfaces: 4–20 mA, Pulse, Modbus RTU (RS485), Modbus TCP (Ethernet), PoE
  • Pressure rating: Up to 30 bar
  • Temperature range:
    Sensor: -30…+180 °C
    Housing: -20…+70 °C
  • Protection rating: IP65
  • Probe material: Stainless steel 1.4301
  • Insertion lengths: 220 mm, 400 mm; Ø 10 mm
  • Installation range: Suitable for pipe diameters from ½" to 40"
 
Back
  • TEL02-27858872
  • Emaillastronic@hotmail.com
  • Address1F, No. 5, Lane 191, Kunyang Street, Nangang District, Taipei City, Taiwan
FOLLOW US
256 bit SSL Encryption
Recommend using Chrome, Firefox, Safari latest version of the browser.
Designed by MIRACLEWeb Design
go top
Contact us
Contact us