VA550 Insertion flow sesnor-ATEX
Germany- CS instruments
Description:
As the fluid passes over a heated sensor element, it removes heat and causes a change in temperature. By measuring this temperature change, or determining the amount of energy required to maintain a constant temperature of the heating element, the flow rate of the fluid can be accurately calculated.
The VA550 is an industrial-grade thermal mass flow meter, certified with ATEX II 2D Ex tb IIIC T90°C Db explosion-proof protection, and is designed to be waterproof and UV-resistant, making it ideal for harsh environments.
Developed by CS Instruments Germany, the flow meter features a hot-swappable installation design, allowing it to be inserted or removed at any time without system shutdown, while still ensuring accurate measurement of all types of dry gases.
Download file
Gas Measured
- Compressed air (from air compressors)
- Nitrogen (N₂)
- Natural gas flow
- Liquefied petroleum gas (LPG) flow
- Carbon dioxide (CO₂)
- Argon (Ar)
- Biogas
- Vacuum
Advantage
- Insertion design: Enables quick on-site installation and removal for maintenance without interrupting the pipeline system.
- Robust, impact-resistant aluminum die-cast housing: Suitable for outdoor environments, with IP67 protection rating.
- Corrosion-resistant wetted parts: All medium-contact components are made of stainless steel 1.4571.
- Portable flow meter: Suitable for pipelines with diameters from ¾” to DN500.
- Explosion-proof certification: Complies with ATEX II 2G Ex d IIC T4 standards.
- Gas certification: Approved by DVGW Germany for natural gas up to 16 bar.
- Pressure range: Up to 50 bar, with special models up to 100 bar.
- Temperature range: Up to 180°C.
- Easy installation and removal under pipeline pressure: Uses a ½” ball valve.
- Rotatable display: Screen can rotate 180° for flexible viewing.
Technical data
- Accuracy: ±1.5% of measured value (m.v.)
- Power supply: 18…36 VDC, 5 W
- Communication interfaces: 4–20 mA, Pulse, Modbus RTU (RS485), Modbus TCP (Ethernet), PoE
- Pressure rating: 50 bar (optional up to 100 bar)
- Temperature range:
- Sensor: -40…+180 °C
- ATEX version: -20…+120 °C
- Protection rating: IP67
- Probe material: Stainless steel 1.4571
- Insertion lengths: 220 mm, 300 mm, 400 mm
- Installation range: Suitable for pipe diameters from ½" to 40"