VA570 Inline flow sensor-ATEX
Germany- CS instruments
Description:
As the fluid passes over a heated sensor element, it removes heat and causes a temperature change. By measuring this temperature change, or determining the energy required to maintain a constant temperature of the heating element, the flow rate of the fluid can be accurately calculated.
The VA570 is an industrial-grade, fixed-type thermal mass flow meter, certified with ATEX II 2D Ex tb IIIC T90°C Db explosion-proof protection, and is designed to be waterproof and UV-resistant.
Installation of the VA570 requires pipeline shutdown, and it can be mounted using either threaded or flange connections.
The VA570 Thermal Mass Flow Meter can be installed at distribution stations, various departments, or individual laboratory buildings to accurately measure gas consumption for each user, facilitating usage calculation and cost allocation. It can also be used to monitor gas consumption for individual machines, helping to analyze equipment efficiency, gas usage, and pipeline leakage.
Download file
Gas Measured
- Compressed air (from air compressors)
- Nitrogen (N₂)
- Natural gas flow
- Liquefied petroleum gas (LPG) flow
- Carbon dioxide (CO₂)
- Argon (Ar)
- Biogas
- Vacuum
Advantage
- Robust, impact-resistant aluminum die-cast housing: Suitable for outdoor environments, with IP67 protection rating.
- Corrosion-resistant wetted parts: All medium-contact components are made of stainless steel 1.4571.
- Explosion-proof certification: Complies with ATEX II 2G Ex d IIC T4 standards.
- Gas certification: Approved by DVGW Germany for natural gas up to 16 bar.
- Maximum pressure: 16 bar (special PN 40 version up to 40 bar).
- Medium temperature range: Up to 180 °C (ATEX version up to 120 °C).
- Installation range: Suitable for DN15 to DN80 pipes, available with flange and threaded connections.
Technical data
- Accuracy: ±1.5% of measured value (m.v.)
- Power supply: 18…36 VDC, 5 W
- Communication interfaces: 4–20 mA, Pulse, Modbus RTU (RS485), Modbus TCP (Ethernet), PoE
- Pressure rating: Up to 40 bar
- Temperature range:
Sensor: -40…+180 °C
ATEX version: -20…+120 °C - Protection rating: IP67
- Probe material: Stainless steel 1.4571
- Threaded installation range: ¼" ~ 2"
- Flange installation range: DN15 ~ DN80