FA 515 / FA 510 Dew Point Sensor
The electronics and dew point sensor of the FA 510/515 stationary dew point transmitter have been further enhanced, particularly regarding temperature compensation.
This means maintaining high-precision dew point accuracy across varying ambient conditions and temperatures, while improving the resolution of the dew point sensor signal.
The FA 510/515 stationary dew point sensor provides outstanding long-term stability and accurate, reliable measurement values. Dew point condensation does not affect sensor precision or readings, and the integrated stainless steel sintered cap protects the FA 510/515 from contamination caused by direct contact with particulate matter.
Product Application
-
Compressed Air Systems
Application: Monitoring dew point temperature in dryers (desiccant, refrigerated). -
Drying Process Monitoring
Industries: Dew point monitoring for plastic injection molding, food processing, pharmaceuticals, and electronics manufacturing. -
Gas Purity Dew Point Monitoring (e.g., N2, H2, O2)
Industries: Semiconductor, chemical, laser, and medical applications. -
Cold Storage & Cold Chain Logistics
Electrical Power Equipment (SF6 Switchgear Gas Monitoring)
Application: Moisture in SF6 gas generates acidic byproducts that degrade electrical insulation equipment. -
Climatic & Environmental Simulation Testing
Applications: Laboratories, automotive component testing, and military equipment environmental durability testing.
FA 515 / FA 510 Dew Point Transmitter Key Advantages
-
Suitable for all types of dryers with a measuring range from -100 to +50 °Ctd dew point.
-
Gas-independent measurement, also suitable for other non-corrosive gases.
-
Compact design, ideal for installation in dryers.
-
Robust design with IP66 protection class.
-
Long-term stability and drift resistance, optimizing calibration intervals.
-
Analog output 4...20 mA (2-wire or 3-wire technology) and Modbus RTU (RS 485) interface.
-
Available in multiple measurement units: pressure dew point [°Ctd], temperature [°C], relative humidity [%RH], absolute humidity [g/m³], moisture content [g/kg], moisture fraction V/V [ppmV/V], water vapor partial pressure [hPa], and atmospheric dew point [°Ctd.atm].
FA 510 / FA 515 Dew Point Transmitter Technical Data
-
Measuring Range: -100 to +50 °Ctd
Dew Point Accuracy:
±1 °Ctd (-20 to +20 °Ctd)
±2 °Ctd (-50 to -20 °Ctd)
±3 °Ctd (-80 to -50 °Ctd)
Operating Pressure: -1 to 50 bar
Operating Temperature: -20 to +70 °C
Power Supply: 24 VDC
Analog Output: 4–20 mA (2-wire) = -20 to +50 °Ctd
Digital Interface: Modbus RTU (RS-485)
Process Connection: G 1/2" thread
Dimensions: Ø 30 mm, L 130 mm