This site uses cookies. For more information, please see our Privacy Policy
Contact Us
Lastronic Corporation
  • About Us
  • Agent Brand
    • CS instruments-Gas flow and quality measurment
    • Datapaq-Oven Temperature Profiling System
    • Lastronic-Own-brand
    • Air Monitor-Flow tube measurment
    • Testo-Flue gas analyzer and flow measurment
    • iButton-Button-type temperature recorder
    • ACR-compact data recorder
    • Trotec-Multi-parameter Environmental Sensor
    • QbyV-Can quality control machine
  • Product Categories
  • Calibration Services
  • Case Studies
  • Latest News
  • Contact Us
  • Monitoring sensors
    • Gas Flow Meter
    • Steam Vortex Flow Meter
    • HVAC Duct Airflow Meter
    • liquid flow meter
    • Dew point measurement
    • Liquid Level Measurement
    • Temperature and Humidity Measurement
    • Pressure gauge + differential pressure gauge
    • Digital Panel Meter
    • Measurement of residual oil particles in piping
    • flow switch
    • thickness gauge
    • Multi-channel data logger
    • Hot tapping on gas pipelines
  • QC and Portable equipment
    • Datapaq Thermal Profiling System
    • iButton Thermochron Data Logger
    • Boiler Combustion Efficiency Analyzer
    • Gas Leak Detector
    • Anemometer
    • Hygrometer
    • Thermometer
    • Noise meter
    • Particle Counter
    • Endoscope
  • Liquid quality monitoring sensors
    • pH meter
    • Oxidation-Reduction Potential meter
    • Conductivity Meter
    • Dissolved Oxygen Meter
    • Water Hardness Tester
    • Turbidimeter
  • LoRa Wireless monitoring system
    • LoRa Wireless Instrumentation and Telemetry Transmission System
  • Gas Flow Meter Case Studies
    • Application of VA500 Thermal Mass Flow Meter in Natural Gas Measurement
MENU
( )
  • 繁中
  • EN
CLOSE
繁中 EN
  • About Us
  • Agent Brand
    • CS instruments-Gas flow and quality measurment
    • Datapaq-Oven Temperature Profiling System
    • Lastronic-Own-brand
    • Air Monitor-Flow tube measurment
    • Testo-Flue gas analyzer and flow measurment
    • iButton-Button-type temperature recorder
    • ACR-compact data recorder
    • Trotec-Multi-parameter Environmental Sensor
    • QbyV-Can quality control machine
  • Product Categories
    • Monitoring sensors
      • Gas Flow Meter
      • Steam Vortex Flow Meter
      • HVAC Duct Airflow Meter
      • liquid flow meter
      • Dew point measurement
      • Liquid Level Measurement
      • Temperature and Humidity Measurement
      • Pressure gauge + differential pressure gauge
      • Digital Panel Meter
      • Measurement of residual oil particles in piping
      • flow switch
      • thickness gauge
      • Multi-channel data logger
      • Hot tapping on gas pipelines
    • QC and Portable equipment
      • Datapaq Thermal Profiling System
      • iButton Thermochron Data Logger
      • Boiler Combustion Efficiency Analyzer
      • Gas Leak Detector
      • Anemometer
      • Hygrometer
      • Thermometer
      • Noise meter
      • Particle Counter
      • Endoscope
    • Liquid quality monitoring sensors
      • pH meter
      • Oxidation-Reduction Potential meter
      • Conductivity Meter
      • Dissolved Oxygen Meter
      • Water Hardness Tester
      • Turbidimeter
    • LoRa Wireless monitoring system
      • LoRa Wireless Instrumentation and Telemetry Transmission System
  • Calibration Services
  • Case Studies
    • Gas Flow Meter Case Studies
      • Application of VA500 Thermal Mass Flow Meter in Natural Gas Measurement
  • Latest News
  • Contact Us
  • Home
  • Agent Brand
  • CS instruments-Gas flow and quality measurment
  • Dewpoint sensors
DP 500 / DP 510 Portable Dew Point Meter
1 / 1

DP 500 / DP 510 Portable Dew Point Meter

CS instruments
Description:

The DP 500 dew point meter with an integrated data logger is the ideal portable service instrument for measuring the dew point of compressed air dryers down to -80 °Ctd. Equipped with a 3.5-inch color graphic touchscreen display, it ensures smooth and easy operation. Its unique color graphic display visualizes real-time dew point curves and records dryer switching behavior over extended periods.

The instrument can store up to 100 million measurement values, complete with date and measuring point location names. Recorded data can be easily exported to a PC via USB flash drive and evaluated using the CS Basic software, allowing you to generate measurement records and service reports quickly and effortlessly at any time.

Download file

Product Application

  • Compressed Air Systems
    Application: Monitoring dew point temperature in dryers (desiccant, refrigerated).

  • Drying Process Monitoring
    Industries: Dew point monitoring for plastic injection molding, food processing, pharmaceuticals, and electronics manufacturing.

  • Gas Purity Dew Point Monitoring (e.g., N2​, H2​, O2​)
    Industries: Semiconductor, chemical, laser, and medical applications.

  • Cold Storage & Cold Chain Logistics

    Electrical Power Equipment (SF6​ Switchgear Gas Monitoring)
    Application: Moisture in SF6​ gas generates acidic byproducts that degrade electrical insulation equipment.

  • Climatic & Environmental Simulation Testing
    Applications: Laboratories, automotive component testing, and military equipment environmental durability testing.


  DP500  Key Advantages

  • Suitable for all types of compressed air dryers across various measuring ranges, such as -80 to +50 °Ctd.

  • Fast response time.

  • 3.5" graphic display with easy operation via touchscreen.

  • Integrated data logger for storing measurement values.

  • USB interface for reading out data using a USB flash drive.

  • Calculates all required moisture parameters, such as g/m³, mg/m³, ppm V/V, g/kg, and °Ctd.atm.

  • Internationalization: Supports up to 8 selectable languages.

  • Available in multiple measurement units: pressure dew point [°Ctd], temperature [°C], relative humidity [%RH], absolute humidity [g/m³], moisture content [g/kg], moisture fraction V/V [ppmV/V], water vapor partial pressure [hPa], and atmospheric dew point [°Ctd.atm].


 

  DP500 Technical Data

  • Measuring Range: -80 to +50 °Ctd

    Accuracy: ±0.5 °Ctd (-10 to +50 °Ctd), typ. ±2 °Ctd (remaining range)

    Operating Pressure: -1 to 50 bar

    Operating Temperature: 0 to +50 °C

    Power Supply: Rechargeable Li-ion battery

    Storage Capacity: 2 GB SD memory card (100 million values)

 
 
Back
  • TEL02-27858872
  • Emaillastronic@hotmail.com
  • Address1F, No. 5, Lane 191, Kunyang Street, Nangang District, Taipei City, Taiwan
FOLLOW US
256 bit SSL Encryption
Recommend using Chrome, Firefox, Safari latest version of the browser.
Designed by MIRACLEWeb Design
go top
Contact us
Contact us